LED Neon Flex Logo

Line Voltage Wave: PVC - 120V

technical data sheet

Legacy Product CODE

NL16E0012WE35K120J

NEW PRODUCT CODE

E2F2W1M2F2AF

PHysical

electrical

11.81in (300mm)
11.81in (300mm)
11.81in (300mm)

operating voltage

120V AC

Circuit type

N/A

power consumption

3.05W/ft (10W/m)

IC Type

3500K

fixture specifications

led function

Static

led chip + CRI

Epistar SMD LED Chip + CRI80

led count

25 LEDs/ft (84 LEDs/m)

temperatureS

Temperature Icon
Ambient Operating
-4°F to 95°F (-20°C to 35°C)
thermal management
Free air convection
Temperature Icon
Ambient installation
32°F to 95°F (0°C to 35°C)
Temperature Icon
max mounting surface
140°F (60°C)
Temperature Icon
fixture storage
-4°F to 140° F (-20°C to 60°C)
Temperature Icon
humidity non condensing
0-95%

Pixel/unit + chip

order unit (Cutting Unit)

max run length

N/A

3.28in (83.3mm) (7 LEDs)

1 Connector
full / dynamic loads

65.6ft (20m) / N/A

2 Connectors
full / dynamic loads

N/A / N/A

safety / testing

jacket/base + LENS color

White + Diffused

testing

Tested to UL2108 Class 2 by Underwriters Laboratory for use in the USA and Canada. Exceeds ANSI C78.377A, CE, and RoHS standards. Must be used under Class 2 ratings to maintain certification.

cord color

White (Black available upon request)

connectors

120V ETL certified: Fuse + Barrel Connectors

mounting

Aluminum: Basic; Recessed; Silicone Grip; Silicone Grip Recessed; Flexible; Raceway; Raceway Suspended. Plastic Reinforced and Stainless Steel Clip.

optical pARAMETERS

color BReakdown

3500K

Fixture cri

80

fixture color tolerance

3 SDCM

wavelength/cct

3465 ± 245K

led cri

82-87

led color tolerance

2.3SDCM

lumen count

128lm/ft (420lm/m)

BEEM angle

lumen maintenance

Round profile 270°

NOTES

*Maximum IP and IK ratings achievable with appropriate accessories.Max run length is based on silicone seamless connectors and excludes connector length—see connector specs for details.PVC products maintain ≤3 SDCM within a production run and <6 SDCM between production runsDouble Feeding is Prohibited.Max run length is based on static full load unless otherwise noted for dynamic use.For runs over 65.62ft (20m), recommended to limit each to 65.62ft for easier handling.

united states

1075 american pacific dr.,
sutie A, henderson, NV 89074

canada

470 Edinburgh Drive
2nd Floor, Moncton nb, E1E 2L1

disclaimer

glls, reserves the right to make any design changes for continuous improvement which will not affect the overall appearance or performance

version
1.0
revision
June 8, 2025
Export PDF/Print Icon